WDMATE
Tempering Mixing Valve 15mm 1/2″ Copper Adjustable 40-50 °c Compatible
Tempering Mixing Valve 15mm 1/2″ Copper Adjustable 40-50 °c Compatible
Regular price
$88.00 AUD
Regular price
Sale price
$88.00 AUD
Unit price
per
Tax included.
Shipping calculated at checkout.
Couldn't load pickup availability
15mm tempering valve copper provide optimumperformance.
When being installed with hot and coldwater supplies of equal dynamic pressure with the water flowing.
It is recommended that the hot and coldwater supplies to each tempering valve be controlled via their own pressurecontrol valve.
In most domestic installations it should bepossible to fit one control valve at the property boundary to control pressureto the whole site.
For commercial installation it isrecommended to fit a pressure control valve on each inlet to the temperingvalve.
The tempering valve must be installed by alicensed plumber and in accordance with as/nzs3500 national plumbing anddrainage code, relevant local government requirements.
Cold water supply temperature: 5°c – 25°c.
Hot water supply temperature: 65°c – 85°c.
Adjustable outlet temperature: 40°c – 50°c.
Factory set temperature: 50°c normal (mustbe commissioned onsite by installer).
Maximum hot water supply temperature 90°c.
Fast response to pressure fluctuation.
Forged dr bronze body.
Advanced polymer components for greaterresistance to calcium deposits.
Integral 60 mesh stainless steel linestrainers.
Integral non return valves.
Stainless steel springs.
O-ring seal inlet union connectors completewith nuts and olives.
Tamper proof adjustment.
Special adjusting tool supplied molded intovalve cap.
Seasonal adjustments not required.
When being installed with hot and coldwater supplies of equal dynamic pressure with the water flowing.
It is recommended that the hot and coldwater supplies to each tempering valve be controlled via their own pressurecontrol valve.
In most domestic installations it should bepossible to fit one control valve at the property boundary to control pressureto the whole site.
For commercial installation it isrecommended to fit a pressure control valve on each inlet to the temperingvalve.
The tempering valve must be installed by alicensed plumber and in accordance with as/nzs3500 national plumbing anddrainage code, relevant local government requirements.
Cold water supply temperature: 5°c – 25°c.
Hot water supply temperature: 65°c – 85°c.
Adjustable outlet temperature: 40°c – 50°c.
Factory set temperature: 50°c normal (mustbe commissioned onsite by installer).
Maximum hot water supply temperature 90°c.
Fast response to pressure fluctuation.
Forged dr bronze body.
Advanced polymer components for greaterresistance to calcium deposits.
Integral 60 mesh stainless steel linestrainers.
Integral non return valves.
Stainless steel springs.
O-ring seal inlet union connectors completewith nuts and olives.
Tamper proof adjustment.
Special adjusting tool supplied molded intovalve cap.
Seasonal adjustments not required.
Materials
Materials
Shipping & Returns
Shipping & Returns
Dimensions
Dimensions




-
Fast Shipping
All our stocks are AU based and all orders will be dispatched next day. We offer fast delivery to most major areas within Australia.
-
Hassle-Free Exchanges
You can purchase with confidence knowing that we have a 100% Satisfaction Guarantee. If something isn't right, or you've just changed your mind, email us within 30 days of purchase for a replacement or credit.*